Home > Products > CVD System
1200℃ hydrogen reduction CVD system with 2-channel float flowmeter to supply gas CY-T1200-100IC-2F-HP

1200℃ hydrogen reduction CVD system with 2-channel float flowmeter to supply gas CY-T1200-100IC-2F-HP

    1200℃ hydrogen reduction CVD system with 2-channel float flowmeter is widely used in materials or chemical laboratories to sinter various new material samples in a hydrogen or hydrogen-nitrogen mixed gas state.

1200℃ hydrogen reduction CVD system can be used for vacuuming and filling atmosphere, so it is also called vacuum tube furnace and atmosphere tube furnace. The tube is made of a seamless nickel-based alloy that can be used for all inert gases and oxygen to 30 PSI (pounds per square foot). In order to match the test requirements for the introduction of hydrogen, the tube furnace is equipped with a manual ignition device at the right end of the furnace tube to ensure the safety of the test; a vacuum gauge and an air pressure gauge are arranged on the left side of the furnace tube to control the vacuum and atmosphere inside the furnace tube. Further safety of the test is ensured by the interlocking of the solenoid valve and the pressure sensor and the flammable gas detection device.

This system also includes a two-channel float flow meter with a stainless steel needle valve and an air pressure gauge to accurately mix the gas that meets the test requirements. Under normal circumstances, this set of instruments is used with a double stage rotary vane vacuum pump to achieve a general low vacuum test environment. If you need a higher vacuum, you can contact our technicians to select a more powerful molecular pump.

1200℃ hydrogen reduction CVD system technical parameters:

Vacuum tube   furnace

Max power

2.5kw

Tube material

Nickel-based alloy

Tube diameter

100mm

Tube length

1000mm

Furnace chamber length

660mm

Heating zone   length

400mm

Constant   temperature zone

200mm

Operating   temperature

0~1100℃

Temperature   control accuracy

±1℃

Temperature   control mode

30 or 50 segment program temperature control

Display mode

LCD

Sealing method

304 stainless steel vacuum flange

Flange interface

1/4" cutting sleeve joint, KF16/25/40 joint

Vacuum

4.4E-3Pa

Power supply

AC:220V   50/60Hz

Ignition device

Manual ignition

Gas supply system

Model

CY-2F

Gas channel

2-channel

Measuring unit

Gas float flowmeter

Measuring range

A channel: 0100ml  H2 gas

Remarks: If you need other ranges or gas types, you need to specify when ordering.

B channel:   16160ml    N2 gas

measurement   accuracy

±2.0%

Pipe pressure resistance

3MPa

Working pressure difference

50300KPa

Connecting   pipe

304 stainless steel

Gas channel

304 stainless steel needle valve

Interface   specification

1/4" cutting sleeve joint for gas inlet and outlet

Exhaust system

Mechanical pump

Rotary vane pump

Pumping rate

1.1L/S   

Exhaust interface

KF16

Vacuum   measurement

Pirani gauge

Ultimate vacuum

1.0E-1Pa

Power supply

AC:220V   50/60Hz

Pumping   interface

KF16

Disclaimer: The product introduction content (including product images, product descriptions, technical parameters, etc.) of this site is for reference only. As the update may not be timely, there will be some differences between the content and the actual situation. Please contact our sales staff to confirm. The information provided on this site does not constitute any offer or promise, and the company will improve and modify any information on the website from time to time without prior notice.

Contact Us
  • E-mail: cysi@cysi.wang
  • Tel: +86 371 5519 9322
  • Fax: +86 371 8603 6875
  • Add: No. 820, 8th Floor, 1st Unit, 9th Block, Cuizhu Street, High-Tech Zone, Zhengzhou, Henan, China
  • Korea Distributor:
    NEO LFN Corp
    Email:info@neolfn.com
    Tel:+82-31-999-4944
    Contact:Haeseop Kim
Follow Us

Copyright © Zhengzhou CY Scientific Instrument Co., Ltd. All Rights Reserved   

| Sitemap |       Technical Support: